PrimaX I The PrimaX I gas detector is designed to detect a wide range of toxic gases and oxygen using electrochemical sensors.
With its innovative housing design, ease of use, quick installation and suitability for indoor and outdoor mounting, the PrimaX I gas detector is the best choice for versatile gas detection. The large display with clear text provides information at a glance.
Calibration is easily performed using the built-in keypad or HART digital communications. With quick-release sensors and integrated mounting plate, quick and easy installation is possible.
The PrimaX I is available in a general purpose or intrinsically safe design in a rugged antistatic reinforced nylon housing with standard 4– 20 mA output and optional HART support.
SIL 2 certified by TUV.
ATEX II 1G Ex ia IIC T4 Ga, II 2D Ex ia IIIC T130 ° C Db IP54, SIL 2 HART registered IECEx, UL, GOST-R, INMETRO.
Gas | Default range | Possible range |
---|---|---|
Methane | 100% NKPR | - |
Propane | 100% NKPR | - |
Oxygen (O 2 ) | 25% vol. | 10% vol. |
Hydrogen sulfide (H 2 S) | 50 ppm | 20, 100 ppm |
Carbon monoxide (CO) | 100 ppm | 200, 500,1000 ppm |
Ammonia (NH 3 ) | 500 ppm | |
Ammonia (NH 3 ) | 100 ppm | |
Chlorine (Cl 2 ) | 10 ppm | 5 ppm |
Sulfur dioxide (SO 2 ) | 10 ppm | 100 ppm |
Hydrogen cyanide (HCN) | 50 ppm | 20 ppm |
Hydrogen Chloride (HCl) | 20 ppm | - |
Hydrogen (H 2 ) | 1000 ppm | - |
Nitrogen dioxide (NO 2 ) | 100 ppm | - |
Specifications | Last OPIR-5 |
---|---|
Settling time T90 | < 5 |
Accuracy rel. | < ± 5% |
Linearization | ≤ ± 5% or ± 10% |
Distance | 100 m standard, 150 m and 200 m extended |
Ambient temperature | -60° C … +75° C * |
sunlight | Any conditions |
Fog | Max opacity - 90%, error ± 10% |
Measuring ranges | 0-5,000 ppm * m, 0-5% NCPR * m (Methane) 0-2,000 ppm * m, 0-1% NCPR * m (Propane) |
Supply voltage | 20-36V |
Energy consumption (average) | 500 mA source, 400 mA sink nominal at 24 V |
Certification | ATEX Ex d IIB+H2 T4 Gb, CSA, FM, IECex, ГОСТ, II 2GD Exd IIB+H2 |
Output signals | 4-20mA, Relay, Modbus, (HART optional) |