Ultima X5000

Ultima X5000

Brand name: MSA

Цена по запросу

В наличии


The Ultima X5000 Gas Analyzer has a number of unique and rare features:

  1. Trucal - self-calibration of the Digital XCell electrochemical sensor for H 2 S and CO for 18 months without using a gas mixture;
    Attention! The Diffusion Supervision, Trucal functions are relevant only for electrochemical sensors based on H 2 S and CO.
  2. Two sensors (in any combination) that can be connected to one transmitter. Naturally, only one sensor can be connected to the transmitter;
  3. Diffusion Supervision - ultrasonic self-monitoring of contamination of the gas-transmitting surface of the Digital XCell electrochemical sensor for H 2 S and CO (you can choose sensors without this function);
  4. 3 years warranty for Digital XCell (H 2 S, CO, O 2 , catalytic) and Ultima XIR infrared sensors;
  5. 10-year warranty for radiation sources of Ultima XIR infrared sensors;
  6. The service life of Digital XCell sensors (H 2 S, CO, O 2 , catalytic) is more than 5 years;
  7. Possibility of replacing Digital XCell sensors (H 2 S, CO, O 2 , catalytic) in an explosive area (on the same device), without disconnecting the device' s power supply;
  8. Possibility of replacing a plug-in unit with an electrochemical sensitive element of Digital XCell sensors (H 2 S, CO, O 2 ) with a plug-in unit with a catalytic sensing element in an explosive zone (on the same device, without changing the display module), without turning off the power of the device;
  9. Toggle on the display of the Ultima X5000 with your finger through the custom function glass;
  10. Bluetooth for remote access to custom gas analyzer functions from a smartphone;
  11. Bright OLED display.

Display

Access to display functions without additional devices.

  • Left touch button - scrolls through menus
  • Right touch button - enter

Ultima X5000 with Bluetooth function

  • Can be ordered without this option 
    Works at a distance of up to 23m
  • Up to 25 devices are stored in memory

Pulse Check technology

  • During initial calibration, the sensor memorizes the output signal characteristic of the calibration curve
  • Pulse Check sends a short electrical signal through the electrical circuits of the sensor
  • The sensor response to the test signal is compared with the calibration response
  • This process takes less than 1 second and is carried out 4 times a day.

Ultima X5000. Flexibility in the selection of sensor combinations

Ultima X5000. SafeSwap function flexibility when replacing sensors

The SafeSwap function allows a used sensor to be replaced with a new calibrated sensor directly in the hazardous area without disconnecting the power supply.

Additional materials: Booklet

User's manual

Have questions?

Similar equipment:

Prima X I

Prima X I

MSAPrima X I
Цена по запросу
More details
Flame detectors FL4000H

Flame detectors FL4000H

MSAFL4000H
Цена по запросу
More details
Ultrasonic leak detector OBSERVER-i

Ultrasonic leak detector OBSERVER-i

MSAOBSERVER-i
Цена по запросу
More details
Prima X P

Prima X P

MSAPrima X P
Цена по запросу
More details
[an error occurred while processing the directive]