FLOW ANALYZERS FOR OIL AND PETROLEUM PRODUCTS IN WATER " TECHNOTOS" SERIES
A new generation of innovative products for the dynamic oil and gas market.
Analyzer " TECHNOTOS" is one of the latest developments to ensure the reliability and simplicity of measuring the content of oil and oil products in water
This technology provides continuous and highly accurate concentration measurement even under extreme climatic and process conditions.
MEASURING RANGE:
0.001 - 1000 mg / l
ANALYZERS ARE AVAILABLE IN THE FOLLOWING VERSIONS:
Benefits and Features:
FOR SPECIFIC CASES, AN OPTION HAS BEEN DEVELOPED WITH THE FOLLOWING ADDITIONAL FEATURES:
Model | TECHNOTOS-BB | TECHNOTOS-BB | TECHNOTOS-V | TECHNOTOS-S |
Installation method | Directly to the pipeline in hazardous areas | Bypass in hazardous areas | Directly to the pipeline in safe areas | Bypass in safe areas |
Measurement method, response time | Laser-induced fluorescence with spectral verification, continuous measurement | Laser-induced fluorescence with spectral verification, continuous measurement | Laser-induced fluorescence with spectral verification, continuous measurement | Laser-induced fluorescence with spectral verification, continuous measurement |
Ambient temperatures environment, ° С | -20 ... + 60 | -20 ... + 60 | -20 ... + 60 | -20 ... + 60 |
Working temperatures, ° С | -20 ... + 200 | -20 ... + 200 | -20 ... + 200 | -20 ... + 200 |
Working pressures (calculated), bar, g | < 100 | < 100 | < 100 | < 100 |
Working pressures (standard), bar, g | < 10 | < 10 | < 10 | < 10 |
Permissible humidity | 93% at 55 ° C | 93% at 55 ° C | 93% at 55 ° C | 93% at 55 ° C |
Explosion protection version | 2014/34/EU ATEX Directive Exd IIG Class 1 Division 1, Zone 1 Ex db [op is T6 Gb] IIB T3 Gb Ta=-20° С to 60° С | 2014/34/EU ATEX Directive Exd IIG Class 1 Division 1, Zone 1 Ex db [op is T6 Gb] IIB T3 Gb Ta=-20° С to 60° С | GENERAL PROM | GENERAL PROM |
Dust and moisture protection | IP66 / IP68 (housing / probe) | IP66 | IP66 | IP66 |
Manufacturing material | 316L SS (others on request) | 316L SS (others on request) | 316L SS (others on request) | 316L SS (others on request) |
Range | ppb - 10000 ppm | ppb - 10000 ppm | ppb - 10000 ppm | ppb - 10000 ppm |
Range Accuracy | ± 1% | ± 1% | ± 1% | ± 1% |
Probe length / body diameter, m | 0.3-5.00 / 0.145 | - | 0.3-5.00 / 0.141 | - |
Dimensions (HxWxD), mm | - | 380.4 x 268 x 182.5 | - | 300 x 350 x 152 |
Weight, kg | depends on the length of the probe | ~ 27.5 | depends on the length of the probe | ~ 27.5 |
Output signals | 2x4-20 mA, 2 alarm relays, Ethernet, HART (optional) | 2x4-20 mA, 2 alarm relays, Ethernet, HART (optional) | 2x4-20 mA, 2 alarm relays, Ethernet, HART (optional) | 2x4-20 mA, 2 alarm relays, Ethernet, HART (optional) |
Process connection | Flange 2 " ANSI (others on request) | ¾ " NPT thread (others on request) | Flange 2 " ANSI (others on request) | ¾ " NPT thread (others on request) |
Power supply | 24V DC | 24V DC | 24V DC | 24V DC |